TBX(Z)ZO-HFVO

Cable Structure

  1. Conductor: Copper wire class 2, IEC 60228, see table
  2. Separator: Mica tape
  3. Insulation: XLPE, according to IEC 60092-351
  4. Individual pair shield: Metalized polyester tape with drain wire
  5. Separator: As required
  6. Common shield: Metalized polyester tape with drain wire
  7. Inner cover: Tape wrapped with overlap, halogen-free, non-hygroscopic
  8. Armoring: Braid of copper wires (min density 90%)
  9. Sheath: Polyolefin, type SHF 1 according to IEC 60092-359 (SHF 2 upon request)

Sheath Color: Gray or orange

Insulation Colors: White or black, with numbers: 1, 2…n

Pair Construction: 1-2; 3-4; 5-6

MARKING ON SHEATH:
ELKA CS ATOX-MARIN TBX(Z)ZO-HFVO nxSmm² 60 V/250 V (or 0.6/1 kV) IEC 60092-350, IEC 60092-376, IEC 60332-3A
or (IEC 60092-353, IEC 60332-3A)

Field of Application
Marine industry.

Technical Data
Nominal voltage: 60 V, 250 V, 0.6/1 kV
Test voltage: 1500 V, 1500 V, 3.5 kV
Standards: IEC 60092-350, IEC 60092-353, IEC 60092-376
Max operating temperature of conductor: 90° C
Flammability testing: IEC 60332-1, IEC 60332-3A
Corrosion testing: IEC 60754-1
Smoke density testing: IEC 61034

Related products

TBX(Z1)OZO-HFTG

Telecommunications, Armored, Low-Flame Propagation Halogen-Free Cable with Common Shield for 60 V, 250 V, and 0.6/1 kV

Standards: IEC 60092-350, IEC 60092-353, IEC 60092-376

BXZO-HFVO

Armored, Fire-Resistant, Halogen-Free Cable 0.6/1 kV

Standards: IEC 60092-350, IEC 60092-353

BXO-HFVO pt

Unarmored, flame-retardant halogen-free cable 0.6/1 kV

Standards:
IEC 60092-350, IEC 60092-353

TBX(Z)OZO-HFVO

Telecommunication, armored, flame-retardant halogen-free cable with individual and common screen for 60 V, 250 V, and 0.6/1 kV

Standards:

IEC 60092-350
IEC 60092-353
IEC 60092-376