Armored, Low-Flame Propagation, Halogen-Free Cable 0.6/1 kV
Standards: IEC 60092-350, IEC 60092-353
Cable Structure
- Conductor: Copper wire, class 2, IEC 60228 (50-300 mm², round or sector-shaped), see table.
- Separator: As required.
- Insulation: XLPE, according to IEC 60092-351.
- Inner Covering: Wrapped tape with overlap, halogen-free, non-hygroscopic.
- Armoring: Braided copper wires (minimum density 90%).
- Sheath: Polyolefin, type SHF 1 according to IEC 60092-359 (SHF 2 on request).
Sheath Color: Black or grey.
Insulation Colors:
- Single-core: Black or grey.
- Two-core: Black, blue.
- Three-core: Black, blue, brown (or green/yellow).
- Four-core: Black, blue, brown, white (or green/yellow).
- Five-core: Black, black, blue, brown, white (or green/yellow).
- Seven-core and multi-core: White or black with numbers 1 … n.
Marking on Sheath:
ELKA CS ATOX-MARIN BXZO-HFTG nxSmm² 0.6/1 kV IEC 60092-353, IEC 60332-3A
Field of Application:
Marine industry.
Technical Data:
- Rated Voltage: 0.6/1 kV
- Test Voltage: 3.5 kV
- Standards: IEC 60092-350, IEC 60092-353
- Max Operating Temperature of Conductor: 90° C
- Flame Testing: IEC 60332-1, IEC 60332-3A
- Corrosion Testing: IEC 60754-1
- Smoke Density Testing: IEC 61034