Shielded, medium-voltage, armored, fire-resistant halogen-free cable for 3.6/6 and 6/10 kV
IEC 60092-350, IEC 60092-354
Structure of the Cable
- Conductor: Tinned round copper wire, class 2, IEC 60228, see table
- Semi-conductive layer: SC XLPE
- Insulation: XLPE, according to IEC 60092-351
- Screen: Copper tape or copper wire
- Filler and inner sheath: Polyolefin-based mixture
- Armoring: Braid of tinned copper wires (min density 90%)
- Sheath: Polyolefin, type SHF 1 according to IEC 60092-359 (SHF 2 on request)
- Sheath color: Black or red
MARKING ON THE SHEATH:
ELKA CS ATOX-MARIN BXHOZO-HFTG nxSmm²
Application Area
Marine industry.
Technical Data
- Rated voltage: 3.6/6 kV, 6/10 kV
- Test voltage: 11 kV, 15 kV
- Standards: IEC 60092-350, IEC 60092-354
- Max operating temperature of conductor: 90°C
- Flame testing: IEC 60332-1, IEC 60332-3A
- Corrosion testing: IEC 60754-1
- Smoke density testing: IEC 61034
Marking on the sheath:
ELKA CS ATOX-MARIN BXHOZO-HFTG nxSmm²